Displays the history for past 10 times of ProCon results code detected by the rear TM/ID sensor.
The code is 2 digits per color from left, in the order of YMCK.
SP3-400-001 to 004 (Toner Supply Type: Select; Bk, C, M, Y)
Selects the toner supply mode.
0: FIXED, 2: PID, 3: DANK (Vtref Fixed) , 4: DANK (Vtref Correction)
SP3-530-001 to 008 (PowerON ProCon :Set)
Specifies the non-use time setting, temperature, relative humidity, absolute humidity or page
interval as the threshold of process control execution determination at power on.
SP3-531-001 to 004 (Non-useTime Procon :Set)
Specifies the non-use time setting, temperature, relative humidity, absolute humidity or page
interval as the threshold of process control execution determination for during the stanby-mode.
SP3-533-001 (Interrupt ProCon :Set: Interval:Set:BW)
Specifies the number of sheets interval for Interrupt Pro-Con (BW).
SP3-533-002 (Interrupt ProCon :Set: Interval:Disp:BW)
Displays the number of sheets interval for Interrupt Pro-Con (BW).
SP3-533-003 (Interrupt ProCon :Set: Corr(Short):BW)
Specifies the correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (BW).
SP3-533-004 (Interrupt ProCon :Set: Corr(Mid):BW)
Specifies the correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (BW).
SP3-533-011 (Interrupt ProCon :Set: Interval:Set:FC)
Specifies the number of sheets interval for Interrupt Pro-Con (FC).
SP3-533-012 (Interrupt ProCon :Set: nterval:Disp:FC)
Displays the number of sheets interval for Interrupt Pro-Con (FC).
SP3-533-013 (Interrupt ProCon :Set: Corr(Short):FC)
Specifies the correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (FC).
SP3-533-014 (Interrupt ProCon :Set: Corr(Mid):FC)
Specifies the correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (FC).
SP3-534-001 (JobEnd ProCon :Set: Interval:Set:BW)
Specifies the number of sheets interval for Job end Pro-Con (BW).
SP3-534-002 (JobEnd ProCon :Set: Interval:Disp:BW)
Displays the number of sheets interval for Job end Pro-Con (BW).
SP3-534-003 (JobEnd ProCon :Set: Corr(Short):BW)
Specifies the correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (BW).
SP3-534-004 (JobEnd ProCon :Set: Corr(Mid):BW)
7. Detailed Descriptions