2-195-001
ON/OFF *ENG [0 or 1 / 1 / 1/step]
0: OFF
1: ON
2-195-002 Page: Interrupt: BW+FC *ENG [0 to 999 / 50 / 1page/step]
2-195-003 Page: Interrupt: FC *ENG [0 to 999 / 50 / 1page/step]
2-195-004 Temperature 4 *ENG [0 to 100 / 1 / 1deg/step]
2-195-005 Temperature 5 *ENG [0 to 100 / 1 / 1deg/step]
2220 [Skew Origin Set]
2-220-001 M: Skew Motor ENG [0 or 1 / 0 / 1/step]
2-220-002 C: Skew Motor ENG [0 or 1 / 0 / 1/step]
2-220-003 Y: Skew Motor ENG [0 or 1 / 0 / 1/step]
2221 [LD Power: Fixed]
2-221-001 K *ENG [0 to 217 / 100 / 1%/step]
2-221-002 C *ENG
2-221-003 M *ENG
2-221-004 Y *ENG
2230 [QL Power Setting]
2-230-001 Standard Speed *ENG [0 to 100 / 26 / 1%/step]
2-230-002 Middle Speed *ENG [0 to 100 / 13 / 1%/step]
2-230-003 Low Speed *ENG [0 to 100 / 13 / 1%/step]
2229 [Develop DC Bias]
2-229-001 Standard Speed: Bk *ENG [0 to 800 / 550 / 1-V/step]
2-229-002 Standard Speed: C *ENG [0 to 800 / 550 / 1-V/step]
2-229-003 Standard Speed: M *ENG [0 to 800 / 550 / 1-V/step]