60 and lager
Potential adjust
61 LD won’t light P patter is not written.
62 Residual potential:Vr error Vr>Max
63
Electrified potential:Vd adjust
error
Vd can not be adjusted in target
range.
64
Exposure potential:Vpl adjust
error
Vpl can not be adjusted in
target range
90 and lager
Result(End)
90 Potential not adjust
Potential control method is set
as [0:FIX]
99 Kill
Kill by door open, power off,
error.
(Set when execute.)
Execute result sample (In order of YMCK from left)
Factory default(SP default):[00,00,00,00]
Starting adjust:[99,99,99,99]
Fail Vsg adjust(Y):[21,99,99,99]
Error of Develop gamma Max(C):[99,99,55,99]
Succeed:[11,11,11,11]
3014 [IBACC OK?]