3-600-002 LD Control *ENG [0 to 3 / 1 / 1/step]
3-600-003 TC Adj. Mode *ENG [0 to 4 / 4 / 1/step]
3-600-004 ACC Before ProCon *ENG [0 to 3 / 2 / 1/step]
3-600-010 ActivePotentialControl *ENG [0 to 1 / 1 / 1/step]
3-600-030 IBACC:ON/OFF *ENG [0 to 1 / 1 / 1/step]
3-600-060
Vsg ITB Internal Circumference
Correction
*ENG
[0 to 1 / 1 / 1/step]
3-600-080
Background Pot
ProCon:ON/OFF setting
*ENG
[0 to 1 / 1 / 1/step]
3610 [Chrg AC Control]
3-610-001 Std Speed: K *ENG [0 to 3 / 2.2 / 0.01kV/step]
3-610-002 Std Speed: C *ENG
3-610-003 Std Speed: M *ENG
3-610-004 Std Speed: Y *ENG
3611 [Chrg DC Control]
3-611-001 Std Speed: K *ENG [300 to 1000 / 690 / 1-V/step]
3-611-002 Std Speed: C *ENG [300 to 1000 / 690 / 1-V/step]
3-611-003 Std Speed: M *ENG [300 to 1000 / 690 / 1-V/step]
3-611-004 Std Speed: Y *ENG [300 to 1000 / 690 / 1-V/step]
3-611-011 Mid Speed: K *ENG [300 to 1000 / 690 / 1-V/step]
3-611-012 Mid Speed: C *ENG [300 to 1000 / 690 / 1-V/step]
3-611-013 Mid Speed: M *ENG [300 to 1000 / 690 / 1-V/step]
3-611-014 Mid Speed: Y *ENG [300 to 1000 / 690 / 1-V/step]
3-611-021 Low Speed: K *ENG [300 to 1000 / 690 / 1-V/step]
3-611-022 Low Speed: C *ENG [300 to 1000 / 690 / 1-V/step]
3. Engine SP Mode Tables