3-623-053 Low Speed intercept:M
*ENG [-1000 to 1000 / * / 1/step]
*MP C3004: 0
*MP C3504: 0
*MP C4504: -15
*MP C5504: -15
*MP C6004: -15
3-623-054 Low Speed intercept:Y
*ENG [-1000 to 1000 / * / 1/step]
*MP C3004: 0
*MP C3504: 0
*MP C4504: -15
*MP C5504: -15
*MP C6004: -15
3624 [TC Adj. Mode]
3-624-001 Target(Upp Limit) *ENG
[0 to 1 / 0.15 / * / 0.01mg/cm
2
/-
kV/step]
*MP C3004: 0.15
*MP C3504: 0.15
*MP C4504: 0.01
*MP C5504: 0.01
*MP C6004: 0.01
3-624-002 Target(Lwr Limit) *ENG
[-1 to 0 / -0.12 / * / 0.01mg/cm
2
/-
kV/step]
*MP C3004: 0.15
*MP C3504: 0.15
*MP C4504: 0.01
*MP C5504: 0.01
*MP C6004: 0.01
3-624-021 Consumption Pat: DUTY: K *ENG [0 to 15 / 15 / 1/step]
3-624-022 Consumption Pat: DUTY: C *ENG [0 to 15 / 15 / 1/step]
3-624-023 Consumption Pat: DUTY: M *ENG [0 to 15 / 15 / 1/step]