5-803-061 Development Motor K: Lock ENG [0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of developer motor (K).
(0: Running, 1: Stopped, or locked)
5-803-063 Development Motor FC: Lock ENG [0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of developer motor (FC).
(0: Running, 1: Stopped, or locked)
5-803-064 Drum Motor FC: Lock ENG [0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of drum motor (FC).
(0: Running, 1: Stopped, or locked)
5-803-065 Fusing Motor: Lock ENG [0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of fusing motor.
(0: Running, 1: Stopped, or locked)
5-803-066 Transfer Drum Motor K: Lock ENG [0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of transfer drum motor K.
(0: Running, 1: Stopped, or locked)
5-803-068 PP:CB:SC Detection ENG [0 or 1 / 0 / 1/step]
0: SC detected
1: Normal
Detects SC of HVP (electrify/develop).
(0: SC detected, 1: Normal)
Input and Output Check
569