5-307-00
4
Rule Set (End) - -
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5401 [Access Control]
5-401-103 Default Document ACL CTL [0 to 3 / 0 / 1]
5-401-104 Authentication Time CTL [0 to 255 / 0 / 1sec/step]
5-401-162 Extend Certification Detail CTL [0 to 0xff / 0 / 1]
5-401-200 SDK1 UniqueID CTL [0 to 0xFFFFFFFF / 0 / 1]
5-401-201 SDK1 Certification Method CTL [0 to 0xFF / 0 / 1]
5-401-210 SDK2 UniqueID CTL [0 to 0xFFFFFFFF / 0 / 1]
5-401-211 SDK2 Certification Method CTL [0 to 0xFF / 0 / 1]
5-401-220 SDK3 UniqueID CTL [0 to 0xFFFFFFFF / 0 / 1]
5-401-221 SDK3 Certification Method CTL [0 to 0xFF / 0 / 1]
5-401-230 SDK Certification Device *CTL [0 to 7 / 0 / power of 2]
0-1: SDK authentication available
0-0: Disable all functions
1-1: SKB Display
1-0: Disable
2-1: Administrator login
2-0: Disable
3 to 7-0: Reserved (set “0” only)
Controller SP Tables-5
625

Table of Contents