EasyManua.ls Logo

Ricoh MP C3004 - Page 925

Ricoh MP C3004
2154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC No. Type Error Name/Error Condition/Major Cause/Solution
Motor defective
Connector disconnected
Harness broken
IOB defective
Replace the paper exit cooling fan.
Reconnect the connector.
Replace the harness.
Replace the Imaging IOB.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC540-00 D Fusing Motor: Lock
Motor status is observed at 100ms intervals during motor ON, and the
unlock status is detected at least 20 times.
Motor defective
Connector disconnected
Harness broken
IOB defective
Unit torque increased
Replace the fusing motor.
Reconnect the connector.
Replace the harness.
Replace the Paper Transport IOB.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC541-01 A Thermopile (Center) Disconnection
Below -50 degrees C (or below CB) is detected for specified time (sec.)
continuously.
Thermopile disconnection
Connector disconnected
Service Call 501-584
917

Table of Contents

Related product manuals