SC No. Type Error Name/Error Condition/Major Cause/Solution
SC542-02 A Thermopile (Center) does not reload
(T21) degrees C not reached after fusing lamp 1 ON for specified time
(sec.)
SC542-03 A Thermopile (Center) does not reload
Heating central reload permission temperature not reached after fusing
lamp 1 ON for specified time (sec.)
SC542-05,
-06
D
Thermopile (Center) does not reload (Low Power)
-
Thermopile lens dirt
Thermopile modification/float
Outside input voltage guarantee
After excessive temperature rise prevention unit operation
1. Check the power supply voltage and reconnect the cable to the
outlet.
2. Replace the Thermostat (Center).
3. Reconnect the Fusing Lamp.
4. Replace the Thermopile (Center).
5. Replace the BCU, or PSU (AC controller board).
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC543-00 A Thermopile (Center) high temperature detection (software)
Above (T3) degrees C detected for specified time (sec.) continuously.
Detection period 100ms, detection count: 10 times or more.
Triac short-circuit
IOB board defective
BCU board defective
Service Call 501-584