SC No. Type Error Name/Error Condition/Major Cause/Solution
1. Remove the jammed paper, or slip of paper in Fusing Unit.
2. Check the power supply voltage and reconnect the cable to the
outlet
3. Replace the Thermostat (Center, Edge).
4. Replace the Fusing lamp.
5. Replace the Thermopile (Center, Edge).
6. Replace the BCU, or PSU (AC Controller Board).
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC557-00 C Zero Cross Frequency Exceeded
In the event of an error
Frequency instability of mains power supply /Noise
-
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC558-01 C Low Input Voltage
Input voltage below the specification is detected on the mains power
supply
Low input of mains power supply
-
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC559-00 A Fusing Jam Detected for 3 Times Consecutively
6. Troubleshooting
928