SC No. Type Error Name/Error Condition/Major Cause/Solution
SC650-13 C Remote Service Modem Communication Error (RC Gate Type M was
installed but modem is not present (detected during operation))
An error related to communication (dialup connection, modem
board etc.) using the RC Gate Type M was detected or an error that
prevents RC Gate operation was detected at power on.
Displayed only when an error is detected while RC Gate is
operating.
SC is not issued if an error occurs during RC Gate installation
(because it can be referenced using SP).
RC Gate Type M was installed but modem is not present (detected during
operation)
If a modem board is not installed, install it.
Check again if the modem driver configurations (SP5-816-160,
SP5-816-165 to 171) are correct.
If the problem is not solved, replace the modem.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC650-14 C Remote Service Modem Communication Error (RC Gate Type N was
installed but modem is present or wired/wireless LAN is not working
correctly)
An error related to communication (dialup connection, modem
board etc.) using the RC Gate was detected or an error that
prevents RC Gate operation was detected at power on.
Displayed only when an error is detected while RC Gate is
operating.
SC is not issued if an error occurs during RC Gate installation
(because it can be referenced using SP).
RC Gate Type N was installed but modem is present or wired/wireless
LAN is not working correctly
If a modem board is attached, remove it.
Check if wired/wireless LAN works.
SC620-Service Call 620-689