SC No. Type Error Name/Error Condition/Major Cause/Solution
ID2 stored in the NVRAM has either of the following problems.
• Number of characters is not 17.
• Includes a character that cannot be printed.
• All spaces
• NULL
Replace the NVRAM.
Clear the RC Gate install status, write the common certificate, and then
begin installation again.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-01 D Engine start up error when the machine boots up
• /ENGRDY signal was not asserted when the machine was turned
on.
• PCI I/F is not linked up when the machine returns from energy saver
mode.
• /IPURDY signal was not asserted when the machine was turned on
or returned from energy saver mode.
• EC/PC/SC response was not received within specified time from
power on.
• Writing to Rapi driver failed (the other party not found through PCI).
• Connection defect between controller board and IPU.
• IPU is down / unstable
• BCU is down / unstable
Engine board does not start up.
Refer to page 1066 "When SC670 (Engine start up error) is displayed"
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-02 D Engine start up error when the machine is in operation
SC620-Service Call 620-689
965