SC No. Type Error Name/Error Condition/Major Cause/Solution
ID2 stored in the NVRAM has either of the following problems.
Number of characters is not 17.
Includes a character that cannot be printed.
All spaces
NULL
Replace the NVRAM.
Clear the RC Gate install status, write the common certificate, and then
begin installation again.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-01 D Engine start up error when the machine boots up
/ENGRDY signal was not asserted when the machine was turned
on.
PCI I/F is not linked up when the machine returns from energy saver
mode.
/IPURDY signal was not asserted when the machine was turned on
or returned from energy saver mode.
EC/PC/SC response was not received within specified time from
power on.
Writing to Rapi driver failed (the other party not found through PCI).
Connection defect between controller board and IPU.
IPU is down / unstable
BCU is down / unstable
Engine board does not start up.
Refer to page 1066 "When SC670 (Engine start up error) is displayed"
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-02 D Engine start up error when the machine is in operation
SC620-Service Call 620-689