Remote control commandsMXO 4 Series
807User Manual 1335.5337.02 ─ 07
SBUS<sb>:LIN:FCOunt?
Returns the number of decoded frames.
Suffix:
<sb>
.
1...4, index of the serial bus
Return values:
<Count> Total number of decoded frames.
Usage: Query only
Asynchronous command
SBUS<sb>:LIN:FRAMe<fr>:BITRate?
Returns the primary bit rate.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<PrimaryBitRate> Range: 0 to 100000000000
Increment: 1
*RST: 0
Default unit: bps
Usage: Query only
Asynchronous command
SBUS<sb>:LIN:FRAMe<fr>:BYTE<o>:STATe?
Returns the state of the specified byte.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
<o> index of the byte
Return values:
<FrameByteState> OK | WAKeup | CHCKsum | PRERror | STERror | SYERror |
LNERror | UNK | INComplete
*RST: OK
Usage: Query only
Asynchronous command
SBUS<sb>:LIN:FRAMe<fr>:BYTE<o>:VALue?
Returns the value of the specified byte.