Remote control commandsMXO 4 Series
806User Manual 1335.5337.02 ─ 07
<fr> index of the frame
<fl> index of the field
Parameters:
<Index_Min> Range: 1 to 65535
Increment: 1
*RST: 1
Usage: Asynchronous command
Manual operation: See "Edit" on page 400
SBUS<sb>:LIN:FILTer:IOPerator
<Frame>,<Field>,<Operator>
SBUS<sb>:LIN:FILTer:FRAMe<fr>:FLD<fl>:IOPerator <Index_Operator>
Sets the operator for the index in the selected field of the selected frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
<fl> index of the field
Parameters:
<Index_Operator> EQUal | INRange | RANGe
*RST: INRange
Usage: Asynchronous command
Manual operation: See "Edit" on page 400
17.16.6.4 Decode results
The following chapter describes the commands used for querying the results of the LIN
decoding.
SBUS<sb>:LIN:FCOunt?................................................................................................ 807
SBUS<sb>:LIN:FRAMe<fr>:BITRate?.............................................................................. 807
SBUS<sb>:LIN:FRAMe<fr>:BYTE<o>:STATe?..................................................................807
SBUS<sb>:LIN:FRAMe<fr>:BYTE<o>:VALue?..................................................................807
SBUS<sb>:LIN:FRAMe<fr>:BYTE<o>:COUNt?.................................................................808
SBUS<sb>:LIN:FRAMe<fr>:BYTE<o>:FVALue?................................................................808
SBUS<sb>:LIN:FRAMe<fr>:BYTE<o>:LABel?.................................................................. 808
SBUS<sb>:LIN:FRAMe<fr>:CSValue?............................................................................. 809
SBUS<sb>:LIN:FRAMe<fr>:DATA?..................................................................................809
SBUS<sb>:LIN:FRAMe<fr>:IDPValue?............................................................................ 809
SBUS<sb>:LIN:FRAMe<fr>:IDSTate?.............................................................................. 810
SBUS<sb>:LIN:FRAMe<fr>:IDValue?...............................................................................810
SBUS<sb>:LIN:FRAMe<fr>:STARt?.................................................................................810
SBUS<sb>:LIN:FRAMe<fr>:STATus?............................................................................... 811
SBUS<sb>:LIN:FRAMe<fr>:STOP?................................................................................. 811
SBUS<sb>:LIN:FRAMe<fr>:PIDentifier?........................................................................... 811
Protocols