Remote control commandsMXO 4 Series
850User Manual 1335.5337.02 ─ 07
PBUS<pb>:DECTable:DATA?
Returns a list of decoded values and corresponding points in time from the decode
table. Each data pair corresponds to one clock edge, which is one row in the table. The
decode table is only available for clocked buses.
Suffix:
<pb>
.
1...4, index of the logic group
Usage: Query only
Asynchronous command
Manual operation: See "Show decode table" on page 426
PBUS<pb>:DIGSignals:POSition
<DigChanPosition>
Sets the vertical position of all active digital channels.
Suffix:
<pb>
.
1...4, index of the logic group
Parameters:
<DigChanPosition> Range: 0 to 4294967295
Increment: 1
*RST: 0
Usage: Asynchronous command
PBUS<pb>:DIGSignals:SCALe <RelativeHeight>
Sets the size of the display that is used by each active digital signal.
Suffix:
<pb>
.
1...4, index of the logic group
Parameters:
<RelativeHeight> Range: 2 to 100
Increment: 0.5
*RST: 6.25
Default unit: %
Usage: Asynchronous command
PBUS<pb>:DISPlay:SHBU <ShowBus>
If enabled, the resulting bus signal and bus values are displayed in the diagram.
Suffix:
<pb>
.
1...4, index of the logic group
Parameters:
<ShowBus> ON | OFF
*RST: OFF