Remote control commands
R&S
®
RTE
1481User Manual 1326.1032.02 ─ 20
BUS<m>:UART:POLarity <Polarity>
Defines the idle state of the bus. The idle state corresponds to a logic 1. The transmit-
ted data on the bus is high (high = 1) or low (low = 1) active.
Suffix: 
<m>
.
1..4
Selects the serial bus.
Parameters:
<Polarity> IDLLow | IDLHigh
*RST:  IDLHigh
Usage:  Asynchronous command
BUS<m>:UART:SBIT 
<StopBits>
Sets the number of stop bits: 1; 1.5 or 2 stop bits are possible.
Suffix: 
<m>
.
1..4
Selects the serial bus.
Parameters:
<StopBits> B1 | B15 | B2
*RST:  B1
Usage:  Asynchronous command
BUS<m>:UART:SSIZe <DataBits>
Sets the number of data bits in a message.
Suffix: 
<m>
.
1..4
Selects the serial bus.
Parameters:
<DataBits> Number of data bits. 9 data bits are only possible with parity =
none.
Range:  5  to  9
Increment:  1
*RST:  8
Usage:  Asynchronous command
BUS<m>:UART:PACKets <Packets>
Defines the method of packet separation. A packet is a number of subsequent words in
a date stream.
Protocols