Instrument Function
R&S
®
SMU200A
389Operating Manual 1007.9845.32 ─ 15
"Off"
The signal output begins after elapsing of the processing time and starts
with sample 0, i.e. the complete signal is outputted.
This mode is recommended for triggering of short signal sequences with
signal duration comparable with the processing time of the instrument.
SCPI command:
[:SOURce<hw>]:BB:ARB:TRIGger:EXTernal:SYNChronize:OUTPut
on page 585
Trigger Delay
Sets the trigger signal delay in samples on external triggering or on internal triggering via
the second path.
Sets the trigger signal delay in samples on external triggering.
This enables the R&S Signal Generator to be synchronized with the device under test or
other external devices.
For two-path instruments, the delay can be set separately for each of the two paths.
SCPI command:
[:SOURce<hw>]:BB:ARB:TRIGger[:EXTernal<1|2>]:DELay on page 590
[:SOURce<hw>]:BB:ARB:TRIGger:OBASeband:DELay on page 585
Trigger Inhibit
Sets the duration for inhibiting a new trigger event subsequent to triggering. The input is
to be expressed in samples.
In the "Retrigger" mode, every trigger signal causes signal generation to restart. This
restart is inhibited for the specified number of samples.
This parameter is only available on external triggering or on internal triggering via the
second path.
For two-path instruments, the trigger inhibit can be set separately for each of the two
paths.
SCPI command:
[:SOURce<hw>]:BB:ARB:TRIGger[:EXTernal<1|2>]:INHibit on page 590
[:SOURce<hw>]:BB:ARB:TRIGger:OBASeband:INHibit on page 586
Next Segment Trigger In
The section "Next Segment Trigger" In of the menu is only displayed if a multi segment
waveform is loaded.
Baseband Signal - Baseband Block