EasyManuals Logo
Home>Agilent Technologies>Computer Hardware>N5171B

Agilent Technologies N5171B User Manual

Agilent Technologies N5171B
458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
74 Agilent X-Series Signal Generators SCPI Command Reference
Basic Function Commands
Power Subsystem ([:SOURce]:POWer)
:ALTernate:TRIGger:EXTernal[:SOURce]
Supported N5172B/82B
[:SOURce]:POWer:ALTernate:TRIGger:EXTernal[:SOURce]
BBTRigger1|BBTRigger2|PTRig|EVENt1
[:SOURce]:POWer:ALTernate:TRIGger:EXTernal[:SOURce]?
This command sets the external trigger source for the alternate amplitude signal when
:ALTernate:TRIGger[:SOURce] is set to External.
BBTRigger1
This choice requires an external trigger to the selected rear panel BB TRIG 1BNC to
toggle the RF output power between main and alternate amplitudes.
BBTRigger2 This choice requires an external trigger to the selected rear panel BB TRIG 2 BNC to
toggle the RF output power between main and alternate amplitudes.
PTRig This choice requires an external trigger to the selected rear panel PAT TRIG BNC to
toggle the RF output power between main and alternate amplitudes.
EVENt1 This choice requires an external trigger to the selected rear panel EVENT 1 BNC to
toggle the RF output power between main and alternate amplitudes.
*RST BBTR1
:ALTernate:TRIGger[:SOURce]
Supported N5172B/82B
[:SOURce]:POWer:ALTernate:TRIGger[:SOURce] INTernal|EXTernal
[:SOURce]:POWer:ALTernate:TRIGger[:SOURce]?
This command sets the trigger source for the alternate amplitude signal.
INTernal
The baseband generator triggers each timeslot to output a power level set with either the
user-selected main or alternate amplitude parameter.
This choice requires a baseband generator option. Each timeslot is allowed to output
power with a user-selected main or alternate amplitude.
EXTernal This choice requires an external trigger to the selected rear panel connector (see
:ALTernate:TRIGger:EXTernal[:SOURce]) to toggle the RF output power between main
and alternate amplitudes.
*RST MAN
:ALTernate[:STATe]
Supported N5172B/82B
[:SOURce]:POWer:ALTernate:STATe ON|OFF|1|0
[:SOURce]:POWer:ALTernate:STATe?
Key Entry BB TRIG 1 BNC BB TRIG 2 BNC EVENT 1 BNC PAT TRIG BNC
Key Entry Alt Ampl Trigger

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N5171B and is the answer not in the manual?

Agilent Technologies N5171B Specifications

General IconGeneral
BrandAgilent Technologies
ModelN5171B
CategoryComputer Hardware
LanguageEnglish

Related product manuals