150 Agilent X-Series Signal Generators SCPI Command Reference
System Commands
Route Subsystem (:ROUTe)
:ROUTe:LINE:PTRigger[1]|2:BNC:SOURce?
This command selects a BNC connector to use as an input for the Pattern Trigger In source.
BBTRigger1 This choice sets the BB TRIG 1 connector as the Pattern Trigger In source.
BBTRigger2 This choice sets the BB TRIG 2 connector as the Pattern Trigger In source.
EVENT1 This choice sets the EVENT 1 connector as the Pattern Trigger In source.
PTRigger This choice sets the PAT TRIG connector as the Pattern Trigger In source.
NONE This choice selects no Pattern Trigger In source.
*RST PTR
Key Entry Patt Trig Source
[:CONNectors]:PTRig[:OUTPut]
Supported N5172B with Option 653 or 655, N5182B with Option 656 or 657
:ROUTe[:CONNectors]:PTRig[:OUTPut] M1|M2|M3|M4|NONE
:ROUTe[:CONNectors]:PTRig[:OUTPut]?
This command selects a marker (M1–M4) signal to be routed to the rear panel PAT TRIG connector.
*RST M1
Key Entry Route to Event 1 BNC
[:CONNectors]:BBTRigger[1]|2[:OUTPut]
Supported N5172B with Option 653 or 655, N5182B with Option 656 or 657
:ROUTe[:CONNectors]:BBTRigger[1]|2[:OUTPut] M1|M2|M3|M4|NONE
:ROUTe[:CONNectors]:BBTRigger[1]|2[:OUTPut]?
This command selects a marker (M1–M4) signal to be routed to the specified rear panel BB TRIG 1
or BB TRIG 2 connector.
*RST M1
Key Entry Route to Event 1 BNC
[:CONNectors]:PTRig[:OUTPut]
Supported N5172B with Option 653 or 655, N5182B with Option 656 or 657
:ROUTe[:CONNectors]:PTRig[:OUTPut] M1|M2|M3|M4|NONE
:ROUTe[:CONNectors]:PTRig[:OUTPut]?
This command selects a marker (M1–M4) signal to be routed to the rear panel PAT TRIG connector.
*RST M1
Key Entry Route to Event 1 BNC