EasyManuals Logo
Home>Agilent Technologies>Computer Hardware>N5171B

Agilent Technologies N5171B User Manual

Agilent Technologies N5171B
458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #226 background imageLoading...
Page #226 background image
196 Agilent X-Series Signal Generators SCPI Command Reference
Analog Modulation Commands
Amplitude Modulation Subsystem–Option UNT ([:SOURce])
:AM[1]|2[:DEPTh][:LINear]:TRACk
Supported All models with Option UNT
[:SOURce]:AM[1]|2[:DEPTh][:LINear]:TRACk ON|OFF|1|0
[:SOURce]:AM[1]|2[:DEPTh][:LINear]:TRACk?
This command enables or disables AM depth value coupling between AM paths 1 and 2. When the
depth values are coupled, a change made to one path is applied to both. LINear must be the AM type
for this command to have any affect. To set the AM measurement type, use the :AM[1]|2:TYPE
command.
ON (1) This choice will link the depth value of AM[1] with AM2; AM2 will assume the
AM[1] depth value. For example, if AM[1] depth is set to 15% and AM2 is set to
11%, enabling the depth tracking will cause the AM2 depth value to change to
15%. This applies regardless of the path (AM[1] or AM2) selected in this command
OFF (0) This choice disables coupling and both paths will have independent depth values.
Example
:AM1:TRAC ON
The preceding example enables AM depth coupling between AM path 1 and AM path 2.
*RST 0
Key Entry AM Depth Couple Off On
:AM[:DEPTh]:STEP[:INCRement]
Supported All Models with Option UNT
[:SOURce]:AM[:DEPTh]:STEP[:INCRement] <value><unit>
[:SOURce]:AM[:DEPTh]:STEP[:INCRement]?
This command sets the AM depth step increment.
Range 0.1–100%
Key Entry Incr Set
Remarks The value set by this command is used with the UP and DOWN choices for the
AM depth setting. Refer to :AM[1]|2[:DEPTh][:LINear] command for more
information.
The setting enabled by this command is not affected by signal generator power- on,
preset, or *RST.
:AM[1]|2:EXTernal[1]|2:COUPling
Supported All Models with Option UNT
[:SOURce]:AM[1]|2:EXTernal[1]|2:COUPling AC|DC
[:SOURce]:AM[1]|2:EXTernal[1]|2:COUPling?
This command sets the coupling for the amplitude modulation source through the selected external
input connector.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N5171B and is the answer not in the manual?

Agilent Technologies N5171B Specifications

General IconGeneral
BrandAgilent Technologies
ModelN5171B
CategoryComputer Hardware
LanguageEnglish

Related product manuals