156 Agilent X-Series Signal Generators SCPI Command Reference
System Commands
Status Subsystem (:STATus)
:QUEStionable:CALibration:PTRansition
Supported All Models
:STATus:QUEStionable:CALibration:PTRansition <value>
:STATus:QUEStionable:CALibration:PTRansition?
This command determines which bits in the Data Questionable Calibration Condition Register will set
the corresponding bit in the Data Questionable Calibration Event Register when that bit has a
positive transition (0 to 1).
The variable <value> is the sum of the decimal values of the bits that you want to enable.
Range 0 to 32767
Remarks Refer to the Programming Guide for more information.
:QUEStionable:CALibration[:EVENt]?
Supported All Models
CAUTION This is a destructive read. The data in the register is latched until it is queried. Once
queried, the data is cleared.
:STATus:QUEStionable:CALibration[:EVENt]?
This command returns the decimal sum of the bits in the Data Questionable Calibration Event
Register.
Range 0 to 32767
Remarks The equivalent PTR or NTR filters must be set before the condition register can
set the corresponding bit in the event register.
Refer to the Programming Guide for more information.
:QUEStionable:CONDition?
Supported All Models
:STATus:QUEStionable:CONDition?
This query returns the decimal sum of the bits in the Data Questionable Condition Register. For
example, if the ALC Heater Detector is cold (bit 4), a value of 16 is returned.
Range 0 to 32767
Remarks The data in this register is continuously updated and reflects current conditions.
Refer to the Programming Guide for more information.