306 Agilent X-Series Signal Generators SCPI Command Reference
Arb Commands
Dual ARB Subsystem–N5172B/82B ([:SOURce]:RADio:ARB)
the rear panel PATTERN TRIG IN connector or the PATT TRIG IN 2 pin on the
rear panel AUXILIARY I/O connector. To make the connector selection, see
“:TRIGger[:SOURce]:EXTernal[:SOURce]” on page 307.
For more information on the connectors and on connecting the cables, see the
User’s Guide.
The trigger signal polarity:
gating mode, see “:TRIGger:TYPE:GATE” on page 304
continuous and single modes, see “:TRIGger[:SOURce]:EXTernal:SLOPe” on
page 307
The time delay between when the X- Series signal generator receives a trigger
and when the waveform responds to the trigger. There are two parts to setting
the delay:
setting the amount of delay, see “:TRIGger[SOURce]:EXTernal:DELay” on
page 306
turning the delay on, see “:TRIGger[:SOURce]:EXTernal:DELay:STATe” on
page 307
BUS This choice enables triggering over the GPIB or LAN using the *TRG or GET
commands or the AUXILIARY INTERFACE (USB) using the *TRG command.
*RST EXT
:TRIGger[SOURce]:EXTernal:DELay
Supported N5172B/82B
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:DELay <value>
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:DELay?
This command sets the amount of time to delay the X-Series signal generators response to an
external trigger.
The delay is a path (time) delay between when the X- Series signal generator receives the trigger and
when it responds to the trigger. For example, configuring a trigger delay of two seconds, causes the
X- Series signal generator to wait two seconds after receipt of the trigger before the X- Series signal
generator plays the waveform.
The delay does not occur until you turn it on (see “:TRIGger[:SOURce]:EXTernal:DELay:STATe” on
page 307). You can set the delay value either before or after turning it on.
For more information on configuring an external trigger source and to select external as the trigger
source, see “:TRIGger[:SOURce]” on page 305.
The unit of measurement for the variable <value> is in seconds (nsec–sec).
*RST +1.00000000E–003
Range 1E8 to 3E1
Key Entry Ext Delay Time
Key Entry Trigger Key Ext Bus

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N5171B and is the answer not in the manual?

Agilent Technologies N5171B Specifications

General IconGeneral
BrandAgilent Technologies
ModelN5171B
CategoryComputer Hardware
LanguageEnglish

Related product manuals