Agilent X-Series Signal Generators SCPI Command Reference 163
System Commands
Status Subsystem (:STATus)
:QUEStionable[:EVENt]?
Supported All Models
CAUTION This is a destructive read. The data in the register is latched until it is queried. Once
queried, the data is cleared.
:STATus:QUEStionable[:EVENt]?
This query returns the decimal sum of the bits in the Data Questionable Event Register.
Range 0 to 32767
Remarks The equivalent PTR or NTR filters must be set before the condition register can
set the corresponding bit in the event register.
Refer to the Programming Guide for more information.