182 Agilent X-Series Signal Generators SCPI Command Reference
System Commands
System Subsystem (:SYSTem)
Remarks After setting a new preset language and presetting the instrument, some defaults
may change to the preset values of the instrument indicated by the remote
language.
:PRESet:PERSistent
Supported All
:SYSTem:PRESet:PERSistent
This command sets the states that are not affected by signal generator power–on, preset, or *RST to
their factory default settings.
Key Entry Restore System Settings to Default Values
Remarks For a list of the persistent instrument factory default values refer to the
Programming Guide.
For a comparison of the SCPI preset commands, refer to Table 3- 1, “Preset SCPI
Commands Overview,” on page 178.
:PRESet:TYPE
Supported All
:SYSTem:PRESet:TYPE NORMal|USER
This command defines the Preset hardkey as either factory preset or as the user preset saved in
memory.
NORMal This choice uses the factory–defined defaults when Preset is pressed.
COMP This choice uses the user–defined preset saved in the instrument when Preset is
pressed. Refer to :PRESet:USER and :PRESet:USER:SAVE commands.
Remarks This command will return an error, if the USER parameter is sent without a user
preset saved in the instrument.
:PRESet:USER
Supported All
:SYSTem:PRESet:USER
This command presets the signal generator to the user’s saved state.
Remarks This command presets the signal generator to the saved user–defined state.
For a comparison of the SCPI preset commands, refer to Table 3- 1, “Preset SCPI
Commands Overview,” on page 178.
Key Entry SCPI SMJ100A 8648A/B/C/D E8257D, E8267D, E8663B
SML 3410 Series 8656B, 8657A/B E8241A, E8244A, E8251A, E8264A
SMV E4428C,E4438C SMU200A, SMATE200A 8662A
SMIQ E442xB, E443xB E8247C, E8257C, E8267C 8663A
Key Entry Preset
Key Entry Execute User Preset

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N5171B and is the answer not in the manual?

Agilent Technologies N5171B Specifications

General IconGeneral
BrandAgilent Technologies
ModelN5171B
CategoryComputer Hardware
LanguageEnglish

Related product manuals