Agilent X-Series Signal Generators SCPI Command Reference 41
Basic Function Commands
Frequency Subsystem ([:SOURce])
:FREQuency:CHANnels:NUMBer
Supported All Models
[:SOURce]:FREQuency:CHANnels:NUMBer <number>
[:SOURce]:FREQuency:CHANnels:NUMBer?
This command sets the frequency of the signal generator by specifying a channel number of a given
frequency band.
The channel band and channel state must be enabled for this command to work. Refer to the
:FREQuency:CHANnels[:STATe] command.
Example
:FREQ:CHAN:NUMB 24
The preceding example sets the channel number to 24 for the current band.
*RST +1
Key Entry Channel Number
Range P- GSM Base/Mobile: 1–24
E- GSM and R- GSM Base/Mobile: 1–1023
DCS Base/Mobile: 512–885
PCS Base/Mobile: 512–900
GSM- 450 Base/Mobile: 259–293
GSM- 480 Base/Mobile: 306–340
GSM- 850 Base/Mobile: 128–251
NADC Base/Mobile: 1–1023
800MHz Base/Mobile: 0–640
1500MHz Base/Mobile: 0–960
TETRA 380/390 Mobile: 3600–4000
TETRA 390/4000 Base: 3600–4000
TETRA 410/420 Mobile: 800–1200
TETRA 420/430 Base: 800–1200
TETRA 460/470: 2400 through 2800 2400–2800
TETRA 870/876 Mobile: 600–640
TETRA 915/921 Base: 600–940
PHS Standard: 1–255
DECT Standard: 0–9