Agilent X-Series Signal Generators SCPI Command Reference 305
Arb Commands
Dual ARB Subsystem–N5172B/82B ([:SOURce]:RADio:ARB)
SINGle Each segment in the sequence requires a trigger to play, and a segment plays only
once, ignoring a segment’s repetition value (see “:SEQuence[:MWAVeform]” on
page 300 for repetition information). The following list describes a sequence’s
playback behavior with this choice:
After receiving the first trigger, the first segment plays to completion.
When the waveform receives a trigger after a segment completes, the sequence
advances to the next segment and plays that segment to completion.
When the waveform receives a trigger during play, the current segment plays
to completion. Then the sequence advances to the next segment, and it plays
to completion.
When the waveform receives a trigger either during or after the last segment
in a sequence plays, the sequence resets and the first segment plays to
completion.
CONTinuous Each segment in the sequence requires a trigger to play. After receiving a trigger,
a segment plays continuously until the waveform receives another trigger. The
following list describes a sequences playback behavior with this choice:
After receiving the first trigger, the first segment plays continuously.
A trigger during the current segment play causes the segment to play to the
end of the segment file, then the sequence advances to the next segment,
which plays continuously.
When last segment in the sequence receives a trigger, the sequence resets and
the first segment plays continuously.
Example
:RAD:ARB:TRIG:TYPE:SADV CONT
The preceding example selects the continuous segment advance mode.
*RST CONT
:TRIGger[:SOURce]
Supported N5172B/82B
[:SOURce]:RADio:ARB:TRIGger[:SOURce] KEY|EXT|BUS
[:SOURce]:RADio:ARB:TRIGger[:SOURce]?
This command sets the trigger source.With the multi–baseband generator synchronization slave
selection, this command is unavailable (see page 284 for more information).
For more information on triggering, see “:TRIGger:TYPE” on page 302. The following list describes the
command choices:
KEY This choice enables manual triggering by pressing the front-panel Trigger hardkey.
EXT An externally applied signal triggers the waveform. This is the only choice that
works with gating. The following conditions affect an external trigger:
The input connector selected for the trigger signal. You have a choice between
Key Entry Single Continuous

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N5171B and is the answer not in the manual?

Agilent Technologies N5171B Specifications

General IconGeneral
BrandAgilent Technologies
ModelN5171B
CategoryComputer Hardware
LanguageEnglish

Related product manuals