System messages
Manpack Transceiver 2110 series Reference Manual 377
Power Off: <period of time>
Battery Empty
The transceiver will power down after the specified time. Replace the
battery pack with one that is fully charged, or recharge the battery
pack.
PTT aborted:
confirmations lost
The device that was transmitting (for example, a modem) has been
disconnected. Reconnect the device, then try the task again.
PTT aborted:
timeout period exceeded
The transceiver has ceased transmission because the maximum
transmission time set in the Cfg PTT Cutout Time entry in the Control
List was exceeded. This may have occurred because you held down
PTT for too long or made a long transmission using a modem.
Release the PTT button if it is held down and/or increase the PTT
cutout time if necessary.
PTT rejected
from <location of PTT: reason>
The transceiver could not transmit from a specific location for the
reason stated. The possible locations are the handset, morse key, and
CICS on the 19-way port.
The possible reasons are that:
• you are on a receive-only channel
• the mode is not allowed for this channel
• you are in the CB frequency range but are not on a specific CB
channel
• you are using a transceiver in which the channel programming
option and the position of the TPE link does not permit
transmission
• the system is locked
• the transceiver is scanning
• the battery charge is low
• the synthesiser is unlocked
• the transceiver is tuning
• the maximum transmission time set in the Cfg PTT Cutout Time
entry in the Control List was exceeded
Public Key
Ready
The requested public key exchange for the VP-116 Voice Privacy
Unit has completed.
Public Key Req
Reply?
The VP-116 Voice Privacy Unit attached to your transceiver has
received a request for a public key exchange. Press to accept the
exchange.
Read only entry
Read only list
Read only setting
You have attempted to edit a locked list, entry or setting. The item
was locked at a higher access level than that into which you are
logged. You cannot unlock it unless you log in to that higher level.
For example, if an entry was locked at admin level and you have
logged in as a user, you must log in as an administrator before you can
unlock the entry.
Table 53: System messages (cont.)
Message Description

Table of Contents

Other manuals for Codan 2110 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Codan 2110 series and is the answer not in the manual?

Codan 2110 series Specifications

General IconGeneral
BrandCodan
Model2110 series
CategoryTransceiver
LanguageEnglish

Related product manuals