6.2 Safety precautions
The following safety precautions apply:
Danger 1 — Before working on the power supply unit, verify
whether it is live.
If the power supply is live, which can deliver 48 Vdc, you must
use an insulated tool kit. See 7360 ISAM FX Safety Manual for
more information about working with live components.
Danger 2 — Avoid risk of electric shock.
Always wear protective gloves and footwear for all handling
tasks.
Carefully follow the instructions.
Warning 1 — Before connecting to the power, verify the
specifications of all equipped fan units to ensure that the
correct voltage will be supplied (48 Vdc) to these units.
Warning 2 — Before power is supplied, all fasteners requiring
a specific torque must be tightened moderately before final
tightening with a torque wrench or driver.
When power is supplied, tighten fasteners with insulated tools,
according to the specified torque.
Warning 3 — For Type 2 ports:
The intra-building port(s) of the 7360 ISAM FX equipment or
sub-assembly is suitable for connection to intra-building or
unexposed wiring or cabling only.
Warning 4 — For Type 2 ports that require shielded cables:
The intra-building port(s) of the 7360 ISAM FX equipment or
sub-assembly must use shielded intra-building wiring or
cabling that is grounded at both ends.