2.3 Equipment description
The basic building block of the 7360 ISAM FX is the OLT shelf that houses the
plug-in units. The following types of OLT shelves are supported:
• 7360 ISAM FX-16; shelf with 16 LT slots, 2 NT slots, and one NTIO slot
• 7360 ISAM FX-12; shelf with 12 LT slots, 2 NT slots, and one NTIO slot
• 7360 ISAM FX-8; shelf with 8 LT slots, 2 NT slots, and one NTIO slot
• 7360 ISAM FX-4; shelf with 4 LT slots, 2 NT slots, and one NTIO slot
The following sized racks that can contain 7360 ISAM FX equipment are supported:
• seismic 19 in. rack with 17.5 in. wide shelf mounting space for FX-4, FX-8, and
FX-12 vertical mounting
• EIA standard 19 in. rack with 17.75 in. wide shelf mounting space for FX-4 and
FX-8 horizontal and vertical mounting
• 23 in. standard rack with 21.5 in wide shelf mounting space for FX-4 and FX-8
horizontal and vertical mounting and FX-16 vertical mounting
The following types of OLT shelves are supported for use in combination with the
7360 ISAM WM:
• 7360 ISAM FX-16; shelf with 16 LT slots, 2 NT slots, and one NTIO slot
The following sized racks that can contain 7360 ISAM WM equipment are supported:
• 23 in. standard rack with 21.5 in wide shelf mounting space for FX-4 and FX-8
horizontal and vertical mounting and FX-16 vertical mounting
A shelf is installed in a rack in the central office (CO) or remotely in a controlled
environment vault (CEV).
A fully configured 7360 ISAM FX system consists of one shelf in one rack, network
termination (NT) cards, and line termination (LT) cards. Each shelf is considered a
separate 7360 ISAM FX system. The 7360 ISAM WM consists of one shelf in one
rack, with a controller card, power cards, and up to 12 line cards (LCs).
A fan module is required in each 7360 ISAM FX shelf to provide cooling for the
equipment.