Configuring Inspection Items
FQ2-S/CH User’s Manual
139
4
Setting Up Inspections
Modifying Existing Inspection Items
Deleting Inspection Items
If more than seven inspection items are set, drag the icon at the bottom of the menu upward to display the next
inspection item numbers.
1 Press the number of the inspection item to be
set.
2 Press [Modify] on the menu.
1 Press the number of the inspection item
to be deleted.
2 Press [Delete] on the menu.
Executing Similar Measurements in Different Places.
  Copy an inspection item that is already registered: [Copy].
  Change the name of an inspection item: [Rename].