Logging Measurement Data and Image Data
392
FQ2-S/CH User’s Manual
7-6 Logging Measurement Data and Image Data
FQ2-S1
FQ2-S2
FQ2-S3 FQ2-S4
FQ2-CH
There are two ways to log data.
Recent results logging: Data is temporarily saved in memory inside the Sensor.
File logging: Large amounts of data are saved in SD cards or other external media.
The amounts and types of data that can be logged depend on the logging method that is used, as shown in the
following table.
*1: For recent results logging, the oldest data is overwritten when the maximum number of saved data items is exceeded.
*2: This limit is for one data item.
If more than one data item is logged at the same time, logging can be performed as long as the total number of data items
in all logged data is 32,000 or less.
Logged data
Logged quantity
Recent results logging
*1
File logging
Statistical data
One value (The average value of the mea-
surement results in the collected measure-
ment data is continuously updated.)
Not possible.
Measurement data 1,000 measurement values max.
*2
Up to the capacity of the external memory
Image data 20 images max.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ2-S/CH Series and is the answer not in the manual?

Omron FQ2-S/CH Series Specifications

General IconGeneral
BrandOmron
ModelFQ2-S/CH Series
CategoryDigital Camera
LanguageEnglish

Related product manuals