Inspecting with the Edge Width Inspection Item
286
FQ2-S/CH User’s Manual
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be output to external devices or used in calculations as measurement data.
4-18 Calculations and Judgments Using Inspection Item Data: p. 323
Measurement Data That Can Be Logged for Edge Width
The following values can be logged as measurement data.
*1 When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data: p. 392
Expression
text string
Data name Description Data range
JG Judgement
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
This is the judgment result.
W Edge width 0 to 99999.9999 Edge width
SW Ref. edge width
(reference edge width) 0 to 99999.9999
This is the reference edge width from
when the model was registered.
DF
D. edge width
(difference in edge width)
0 to 99999.9999 This is the difference between the
reference edge width and the mea-
sured edge width.
Measured item Range of value Description
Judgement
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
This is the measurement judgment results.
Edge Width
(edge in width)
−99999.9999 to 99999.9999 This is the difference between the reference width and the
measured edge width.