EasyManua.ls Logo

Omron FQ2-S/CH Series

Omron FQ2-S/CH Series
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inspecting with the Edge Width Inspection Item
286
FQ2-S/CH User’s Manual
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be output to external devices or used in calculations as measurement data.
4-18 Calculations and Judgments Using Inspection Item Data: p. 323
Measurement Data That Can Be Logged for Edge Width
The following values can be logged as measurement data.
*1 When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data: p. 392
Expression
text string
Data name Description Data range
JG Judgement
2: No judgement (not measured)
0: Judgement is OK
1: Judgement is NG
13: Teaching not performed error
14: Figure not registered error
15: Out of range error
This is the judgment result.
W Edge width 0 to 99999.9999 Edge width
SW Ref. edge width
(reference edge width) 0 to 99999.9999
This is the reference edge width from
when the model was registered.
DF
D. edge width
(difference in edge width)
0 to 99999.9999 This is the difference between the
reference edge width and the mea-
sured edge width.
Measured item Range of value Description
Judgement
0: Judgement is OK,
1: Judgement is NG,
13: Teaching not performed error
14: Figure not registered error
15: Out of range error
This is the measurement judgment results.
Edge Width
(edge in width)
99999.9999 to 99999.9999 This is the difference between the reference width and the
measured edge width.

Table of Contents