External Reference Parameters
534
FQ2-S/CH User’s Manual
Edge Position (FQ2-S1/S2/S3 series or FQ2-S4 series only)
700 Display
settings
Correlation display Set / Get 0: Display
1: Do not display
0 --- ---
701 Position X display Set / Get 0: Display
1: Do not display
0 --- ---
702 Position Y display Set / Get 0: Display
1: Do not display
0 --- ---
703 Measurement angle
display
Set / Get 0: Display
1: Do not display
0 --- ---
704 Count display Set / Get 0: Display
1: Do not display
0 --- ---
800 Position X display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0 --- ---
801 Position Y display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0 --- ---
802 Measurement angle
display pattern
Set / Get 0: Absolute value
1: Relative value
0 --- ---
Exter-
nal ref-
erence
number
Category Data name Set / Get Data range Default Expres-
sion
text
string
Logged data/
Judgement
parameter
0Mea-
sure-
ment
result
Judgement Get only 2: No judgement
(not measured)
0: Judgement is OK
1: Judgement is NG
13: Teaching not performed error
14: Figure not registered error
15: Out of range error
2 JG Logged data
5 Edge position X Get only 99,999.9999 to 99,999.9999 0 X Logged data
6 Edge position Y Get only 99,999.9999 to 99,999.9999 0 Y Logged data
7 Standard position X Get only 99,999.9999 to 99,999.9999 0 SX ---
8 Standard position Y Get only 99,999.9999 to 99,999.9999 0 SY ---
9 Difference in position Get only 99,999.9999 to 99,999.9999 0 DF Logged data
103 Output
parame-
ter
Reflect Set / Get 0: Yes, 1: No 0 --- ---
120 Set color Set color Set / Get 0: No edge color specification,
1: Edge color specification
0 --- ---
121 Edge color red Set / Get 0 to 255 255 --- ---
122 Edge color green Set / Get 0 to 255 255 --- ---
123 Edge color blue Set / Get 0 to 255 255 --- ---
132 Mea-
sure-
ment
condi-
tions
Edge level Set / Get 0 to 100 50 --- ---
133 Noise level Set / Get 0 to 442 5 --- ---
External
refer-
ence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter

Table of Contents