External Reference Parameters
502
FQ2-S/CH User’s Manual
Linear Correction
OCR (FQ2-S4 or FQ2-CH series only)
External
refer-
ence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement Get only
−
2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−2JG ---
120 Mea-
sure-
ment
condi-
tions
Position interpolation Set / Get
0: None, 1: Bilinear
1------
122 Source image Set / Get 0: Camera image, 1: Previ-
ous image
1------
Exter-
nal ref-
erence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result Judgement Get only
−
2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
-11: Model mismatch error
-13: Teaching not performed error
−
16: Measurement timeout error
−
17: Format not entered error
−2 JG Logged data
5 Index number Get only −2: No verification pattern
or read was NG,
−1: Verification result is NG
0 to 31: Master data number
0 IN Logged data
6 Number of characters Get only 0 to 128 0 N Logged data
7 Read character string Get only 128 characters max. -- ---
8 Similarity Get only 0 to 100 0 SIM Logged data
9 Stability Get only 0 to 100 0 STB Logged data
103 Output
parame-
ter
Reflect Set / Get 0: Yes
1: No
0 --- ---
110 Reading speed Set / Get 0: Normal
1: Fast
0 --- ---
120 Mea-
sure-
ment
condi-
tions
Character color Set / Get 0: Black
1: White
0 --- ---
121 Dot horizontal interval Set / Get 0 to 30 0 --- ---
122 Dot vertical interval Set / Get 0 to 30 0 --- ---
123 Character thickness
threshold
Set / Get −128 to 128 0 --- ---
124 Boundary correction Set / Get 0: OFF
1: ON
1 --- ---
126 Slender character thresh-
old
Set / Get 1 to 10 3 --- ---
127 Hyphen height upper
threshold
Set / Get 0 to 100 30 --- ---