EasyManua.ls Logo

Omron FQ2-S/CH Series

Omron FQ2-S/CH Series
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
External Reference Parameters
FQ2-S/CH User’s Manual
503
Appendices
9
128 Mea-
sure-
ment
condi-
tions
Hyphen height lower
threshold
Set / Get 0 to 100 70 --- ---
129 Printing type Set / Get 0: Solid character
1: Dot character
1 --- ---
130 Rotation compensation Set / Get 0: OFF
1: ON
0 --- ---
131 Slant compensation Set / Get 0: OFF
1: ON
1 --- ---
132 Judge-
ment
condi-
tions
Similarity judgement upper
limit
Set / Get 0 to 100 100 --- Judgement
condition
133 Similarity judgement lower
limit
Set / Get 0 to 100 60 --- Judgement
condition
134 Stability judgement upper
limit
Set / Get 0 to 100 100 --- Judgement
condition
135 Stability judgement lower
limit
Set / Get 0 to 100 10 --- Judgement
condition
136 Output
parame-
ter
Line delimiter Set / Get 0: None
1: Comma
2: Space
0 --- ---
138 String output ON/OFF Set / Get 0: OFF
1: ON
0 --- ---
139 NG error code output Set / Get 0: OFF
1: ON
1 --- ---
141
*1
Error string Set / Get 20 characters max. NG --- ---
142 Partial output ON/OFF Set / Get 0: No
1: Yes
0 --- ---
143 Output end digit Set / Get 1 to 128 128 --- ---
144 Output beginning digit Set / Get 1 to 128 1 --- ---
146 Mea-
sure-
ment
condi-
tions
Reading speed Set / Get 0: Fixed
1: Variable
1 --- ---
150
*1
Format character string 0 Set / Get 32 characters max. --- ---
151
*1
Format character string 1 Set / Get 32 characters max. --- ---
152
*1
Format character string 2 Set / Get 32 characters max. --- ---
153
*1
Format character string 3 Set / Get 32 characters max. --- ---
154
*1
Teach mode Set / Get 0: Simple teach
1: Correct string
1 --- ---
155
*1
Correct string (L.1) Set / Get 32 characters max. --- ---
156
*1
Correct string (L.2) Set / Get 32 characters max. --- ---
157
*1
Correct string (L.3) Set / Get 32 characters max. --- ---
158
*1
Correct string (L.4) Set / Get 32 characters max. --- ---
160 Dictionary reference Set / Get 1: None
0 to 31
1 --- ---
170 Output
charac-
ter set
String output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0 --- ---
171 NG error code output
(memory link)
Set / Get 0: OFF
1: ON
1 --- ---
172 Partial output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0 --- ---
Exter-
nal ref-
erence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter

Table of Contents