EasyManua.ls Logo

Omron FQ2-S/CH Series

Omron FQ2-S/CH Series
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
External Reference Parameters
504
FQ2-S/CH User’s Manual
173 Output
charac-
ter set
Output end digit
(memory link)
Set / Get 1 to 128 128 --- ---
174 Output beginning digit
(memory link)
Set / Get 1 to 128 1 --- ---
195 Max width setting Set / Get 0: OFF
1: ON
0 --- ---
196 Mea-
sure-
ment
condition
Max width Set / Get 0 to 9999 0 --- ---
197 Max height Set / Get 0 to 9999 0 --- ---
198 Min height Set / Get 0 to 100 50 --- ---
250 Judge-
ment
condi-
tions
Number of characters
upper limit (L.1)
Set / Get 0 to 32 32 --- ---
251 Number of characters
upper limit (L.2)
Set / Get 0 to 32 32 --- ---
252 Number of characters
upper limit (L.3)
Set / Get 0 to 32 32 --- ---
253 Number of characters
upper limit (L.4)
Set / Get 0 to 32 32 --- ---
260 Number of characters
lower limit (L.1)
Set / Get 0 to 32 0 --- ---
261 Number of characters
lower limit (L.2)
Set / Get 0 to 32 0 --- ---
262 Number of characters
lower limit (L.3)
Set / Get 0 to 32 0 --- ---
263 Number of characters
lower limit (L.4)
Set / Get 0 to 32 0 --- ---
300 Logging
condi-
tions
Data logging count Set / Get 1 to 128 128 --- ---
310 Data logging switch (unit) Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
311 Data logging switch
(judgement)
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
312 Data logging switch (mini-
mum similarity)
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
313 Data logging switch (mini-
mum stability)
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
314 Data logging switch (num-
ber of characters 1)
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
315 Data logging switch (num-
ber of characters 2)
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
316 Data logging switch (num-
ber of characters 3)
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
317 Data logging switch (num-
ber of characters 4)
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
318 Data logging switch (simi-
larity (individual))
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
319 Logging
condi-
tions
Data logging switch (stabil-
ity (individual))
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
Exter-
nal ref-
erence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter

Table of Contents

Related product manuals