Inspecting with Color Data Inspection Item
FQ2-S/CH User’s Manual
297
4
Setting Up Inspections
• Sensors with Color Cameras Only
• Sensors with Monochrome Cameras only
Reflect in Total Judgment
You can specify whether to reflect the judgment results of an inspection item in the overall judgment.
[Inspect] [Inspection] [Add item.] [Color Data] [Details] Tab Page [Output parameter]
Item Parameter Setting Description
Judgement
Parameter
Color difference 0 to 442 Sets the upper and lower limits of the difference between the
average color and reference color that is to be judged as OK.
Color deviation 0 to 221 Set the upper and lower limits of the range of the deviation in
the region that is to be judged as OK.
R average 0.0000 to 255.0000 Set the difference in the average value of the R (red) compo-
nent that is to be judged as OK.
G average 0.0000 to 255.0000 Set the difference in the average value of the G (green) compo-
nent that is to be judged as OK.
B average 0.0000 to 255.0000 Set the difference in the average value of the B (blue) compo-
nent that is to be judged as OK.
Item Parameter Setting Description
Judgement
Parameter
Density average 0 to 255 Set the judgment upper and lower limits for the average den-
sity in the measurement region.
Density deviat.
(density devia-
tion)
0 to 127
Set the upper and lower limits for the deviation in the average
density in the measurement region.