External Reference Parameters
FQ2-S/CH User’s Manual
513
Appendices
9
*1: To acquire the detected text string, use the ITEMDATA2 command.
Bar code (FQ2-S4 series only)
2000 Mea-
sure-
ment
result
Number of read characters
on line 1
Get only 0 to 32 0 --- ---
2001 Number of read characters
on line 2
Get only 0 to 32 0 --- ---
2002 Number of read characters
on line 3
Get only 0 to 32 0 --- ---
2003 Number of read characters
on line 4
Get only 0 to 32 0 --- ---
2100 Read character string on
line 1
Get only 32 characters max. --- --- ---
2101
*1
Read character string on
line 2
Get only 32 characters max. --- --- ---
2102
*1
Read character string on
line 3
Get only 32 characters max. --- --- ---
2103
*1
Read character string on
line 4
Get only 32 characters max. --- --- ---
2500+N
(N= 0 to
127*1
Individual read character Get only 1 character --- --- ---
3000+N
(N= 0 to
127)
Individual similarity Get only 0 to 100 0 --- ---
3500+N
(N= 0 to
127)
Individual stability Get only 0 to 100 0 --- ---
External
refer-
ence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter
0Mea-
sure-
ment
result
Judgement Get only 2: No judgement
(not measured),
0: Judgement is OK,
1: Judgement is NG,
16: Measurement timeout error
2 JG Logged data
5 Index No. Get only 2: No verification pattern,
or reading error
1: Verification is NG,
0 to 31: Master data No.
2IN ---
6 Num. of characters Get only 0 to 1024 0 N Logged data
7
*1
Characters Get only 32 characters max. 0 --- ---
103 Output
parame-
ter
Reflect Get only 0: Yes, 1: No 0 --- ---
121 Verifica-
tion con-
dition
Verified master data Set / Get 1: OFF
0: Verify all master data
1: Verify master data 0
2: Verify master data 1
31: Verify master data 31
1 --- ---
122 Partial verif. on/off Set / Get 0: No
1: Yes
0 --- ---
Exter-
nal ref-
erence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter
...

Table of Contents