External Reference Parameters
514
FQ2-S/CH User’s Manual
123 Verifica-
tion con-
dition
Last compared digit Set / Get 1 to 1024 1024 --- ---
124 First compared digit Set / Get 1 to 1024 1 --- ---
125 Output
parame-
ter
String output on/off Set / Get 0: None
1: Enable
0 --- ---
127
*1
Error string Set / Get 20 characters max NG --- ---
128 Partial output on/off Set / Get 0: None
1: Enable
0 --- ---
129 Output last digit Set / Get 1 to 1024 1024 --- ---
130 Output first digit Set / Get 1 to 1024 1 --- ---
131 Mea-
sure-
ment
condition
Code type Set / Get 0: JAN/EAN/UPC
1: Code 39
2: Codabar
3: ITF
4: Code 93
5: Code128/GS1-128
6: GS1 DataBar
7: Pharmacode
0 --- ---
132 Timeout time (ms) Set / Get 1 to 9999 9999 --- ---
133 Check digit on/off Set / Get 0: None
1: Enable
1 --- ---
134 Composite codes on/off Set / Get 0: None
1: Enable
0 --- ---
135 Mea-
sure-
ment
result
Direction Set / Get 0: Horizontal mode
1: Vertical mode
0 --- ---
136 Reverse on/off Set / Get 0: None
1: Enable
0 --- ---
141 Code color Set / Get 0: Black
1: White
0 --- ---
150 Verifica-
tion con-
dition
Selected master num-
ber
Set / Get 1 to 31 0 --- ---
152 Auto master data num-
ber
Set / Get 0 to 31: Master data number
−1: OFF
−1 --- ---
160 Output
parame-
ter
NG error code output Set / Get 0: OFF
1: ON
1 --- ---
170 String output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0 --- ---
171 NG error code output
(memory link)
Set / Get 0: OFF
1: ON
1 --- ---
172 Partial output ON/OFF
(memory link)
Set / Get 0: OFF
1: ON
0 --- ---
173 Output end digit
(memory link)
Set / Get 1 to 1024 1024 --- ---
174 Output beginning digit
(memory link)
Set / Get 1 to 1024 1 --- ---
202+3N
(N=0 to
31)
Verifica-
tion con-
dition
Master data N Set / Get 32 characters max. None --- ---
300+N
(N=0 to
31)
Reference unit number
N
Set / Get 0 to 31 0 --- ---
External
refer-
ence
number
Category Data name Set / Get Data range Default Expres-
sion text
string
Logged data/