Changing the Scene to Change the Line Process
366
FQ2-S/CH User’s Manual
7-1 Changing the Scene to Change the Line Process
FQ2-S3 FQ2-S4
What Are Scenes?
With an FQ2 Sensor, the inspection items that can be processed at the same time are registered as scenes. A
command input from an external device or a touch panel operation can be used to select a certain scene.
If a scene is registered for each type of measurement object or inspection, the line process can be changed
simply by changing the scene when the measurement object or inspection changes.
• Maximum Number of Scenes
• Settings Included with Scenes
The settings that are changed by switching scenes are the Camera image ([Image] Tab Page) and Inspection
Items ([Inspect] Tab Page) output data settings. Settings related to external I/O specifications and the system
settings for the Sensor are used in common for all scenes.
Refer to the following information for the data that is included in the scene data.
9-1 Menu Tables: p. 438
Item FQ2-S2/S3/S4/CH Series FQ2-S1 Series
Number of scenes 32 8
Scene 0
Inspection for
product A
Scene 1
Inspection for
product B
Scene 2
Inspection for
product C
Scene 31
Inspection for
product Z
Cap color
(Inspection item 0:
Color Data)
Label detection
(Inspection item 1:
Search)
Text alignment
(Inspection item 2:
Edge Position)
Line Process Changes:
Example: FQ2-S Series Example: FQ2-S4/CH Series
These can be
registered
as one scene.
Inspection of large
characters
(Inspection item 0:
OCR)
Inspection of small
characters
(Inspection item 1:
OCR)