Changing the Scene to Change the Line Process
366
FQ2-S/CH User’s Manual
7-1 Changing the Scene to Change the Line Process
FQ2-S1
FQ2-S2
FQ2-S3 FQ2-S4
FQ2-CH
What Are Scenes?
With an FQ2 Sensor, the inspection items that can be processed at the same time are registered as scenes. A
command input from an external device or a touch panel operation can be used to select a certain scene.
If a scene is registered for each type of measurement object or inspection, the line process can be changed
simply by changing the scene when the measurement object or inspection changes.
Maximum Number of Scenes
Settings Included with Scenes
The settings that are changed by switching scenes are the Camera image ([Image] Tab Page) and Inspection
Items ([Inspect] Tab Page) output data settings. Settings related to external I/O specifications and the system
settings for the Sensor are used in common for all scenes.
Refer to the following information for the data that is included in the scene data.
9-1 Menu Tables: p. 438
Item FQ2-S2/S3/S4/CH Series FQ2-S1 Series
Number of scenes 32 8
Scene 0
Inspection for
product A
Scene 1
Inspection for
product B
Scene 2
Inspection for
product C
Scene 31
Inspection for
product Z
Cap color
(Inspection item 0:
Color Data)
Label detection
(Inspection item 1:
Search)
Text alignment
(Inspection item 2:
Edge Position)
Line Process Changes:
Example: FQ2-S Series Example: FQ2-S4/CH Series
These can be
registered
as one scene.
Inspection of large
characters
(Inspection item 0:
OCR)
Inspection of small
characters
(Inspection item 1:
OCR)

Table of Contents