Inspecting with the Shape Search II Inspection Item
252
FQ2-S/CH User’s Manual
Select the Results to Output
You can use multiple conditions to determine which results to output from all the objects detected with a
correlation at the candidate level or higher.
Only the results that meet all the specified conditions are output.
[Inspect] [Inspection] [Shape Search II] [Modify] [Details] Tab Page
[Meas. Parameter]
1 Press [Extraction condition] and adjust the
candidate level so that only objects higher
than a certain correlation are detected.
2 Set the conditions for outputting the detected
objects.
(Extraction X/Y and Detection Count)
Extraction condition Range Description
Candidate level 0 to 100
Default: 80
Set the threshold to find Candidate point. Output only
a value that is higher than [Candidate level]. Increase
the value if Model search is unstable.
Extraction X
99999.9999 to 99999.9999
Defaults: Lower: 99,999.9999
Upper: 99,999.9999
Results are output only for objects with a measured X
coordinate that is within this range.
Extraction Y
99999.9999 to 99999.9999
Defaults: Lower: 99,999.9999
Upper: 99,999.9999
Results are output only for objects with a measured Y
coordinate that is within this range.
Detection count 1 to 32
Default: 1
Sets the maximum number of detection results to out-
put.
The processing time changes if you change the candidate level.
Note