Inspecting with the Edge Position Inspection Item
FQ2-S/CH User’s Manual
281
4
Setting Up Inspections
Measurement Data That Can Be Logged for Edge Position
The following values can be logged as measurement data.
* When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data: p. 392
Errors
Errors in Teaching
A teaching error message will appear if the edge position cannot be detected when teaching. Perform the
following.
If the color of the measurement object has changed from the specified color, set the color again and try
teaching again.
If there is an edge and it cannot be detected, adjust the [Noise level] on the [Details] Tab Page and try
teaching again.
Edge Not Found
If an edge is not found, the measurement result will be NG. Perform the following.
If a color was specified, make sure the color of the measurement object has not changed from the specified
color.
Set the color again if necessary.
If there is an edge and it cannot be detected, make sure the [Edge level] parameter on the [Details] Tab Page
is correct.
Edge level: p. 276
Measured item Range of value Description
Judgement
0: Judgement is OK
1: Judgement is NG
13: Teaching not performed error
14: Figure not registered error
15: Out of range error
This is the measurement judgment results.
D. position
(difference in position)
99999.9999 to 99999.9999 This is the offset from the measured reference
position.
Position X 99999.9999 to 99999.9999 This is the X coordinate of the measured edge
position.
Position Y 99999.9999 to 99999.9999 This is the Y coordinate of the measured edge
position.