Calibration
FQ2-S/CH User’s Manual
369
7
Convenient Functions
7-2 Calibration
FQ2-S1
FQ2-S2
FQ2-S3 FQ2-S4
Calibration
Calibration is used to convert Camera coordinates into actual coordinates.
You can set calibration to output the detected position in the actual coordinates.
You can convert pixels to actual dimensions and then output them.
You can also compensate for offsets in the origin and coordinate system.
Calibration Conversion Methods
There are the following three conversion methods for calibration.
Point specification: You can enter the actual pixel coordinates of any position.
Reference: You can measure a registered model and then enter the actual coordinates of the model.
Parameter: You can enter the calibration values directly.
30 mm
540 pixels = 30 mm
Example
Origin of actual coordinates
Origin of Camera coordinates
Example
Camera coordinates
0 X
Y
Origin of
Camera
coordinates
Positive
direction
for angles
Origin of actual
coordinates