Calibration
370
FQ2-S/CH User’s Manual
• Setting Calibration
Use the following procedure to set calibration.
1 Set the conversion method to use for calibration.
Select the calibration method (point specification, reference, or parameter) and enter the actual coordi-
nates or other values that are suitable for the selected method.
You can register up to 32 calibration patterns.
2
Select the calibration pattern to use.
Select the calibration pattern to use from the calibration settings.
Selecting the Calibration Pattern to Use: p. 379
Calibration type Description
Specify point
(point specification)
Specify from three to nine points and enter their actual
coordinates.
p. 371
Reference sampling
(reference)
Search for a registered model and enter the actual
coordinates of the position where the model is
detected.
p. 374
Parameter Enter the numeric values of the parameters directly to
calculate the calibration data.
p. 377
You can set the calibration setting for each scene.
You can use the same calibration setting for different scenes or use a different calibration setting for each scene.
Note