Installation
40
FQ2-S/CH User’s Manual
There is a certain amount of deviation among Sensors in the center of the optical axis. For this reason, when install-
ing the Sensor, check the center of the image and the field of view on the LCD monitor of the Touch Finder and in
the PC Tool.
Removal Procedure
1 Insert a flat-blade screwdriver between the
Mounting Bracket and the Sensor case on ei-
ther side and remove the Mounting Bracket.
6
8 10 12 14
0 20 40 60
50
130
210
0 100 200 300
35
45
55
200
600
1,000
200 400
0
0
400
Horizontal field of view (mm)
Horizontal field of view (mm)
Installation distance (L) (mm)
Installation distance (L) (mm)
FQ2-S@@050F/FQ2-CH1@050F-M
FQ2-S@@100N/FQ2-CH1@100N-M
Horizontal field of view (mm)
Horizontal field of view (mm)
Installation distance (L) (mm)
Installation distance (L) (mm)
FQ2-S@@010F/FQ2-CH1@010F-M
FQ2-S@@100F/FQ2-CH1@100F-M
Installation distance (L)
Vertical field
of view
The optical chart indicates the horizontal field of
view. The vertical field of view depends on the
model as follows:
FQ2-S@@@@@@/FQ2-CH1@@@@@-M:
Approx. 60% of the horizontal field of view
FQ2-S@@@@@@-08@:
Approx. 90% of the horizontal field of view
Horizontal field of view
Note: The tolerance is ±10%.