Reading 2D-codes
FQ2-S/CH User’s Manual
191
4
Setting Up Inspections
Setup Procedure for 2D-code
Step 1 Selecting the Inspection Item
[Inspect] [Inspection]
Step 2 Teaching
For teaching, the region to measure and the 2D code within that region are set as read conditions.
You can also register the contents that was read from the 2D code as a verification condition in the master
data.
Step 3 Verification Conditions: p. 194
[Inspect] [Inspection] [Add item.] [2D-code] [Settings] Tab Page
1 Press an unused inspection item number and press [Add item.].
2 Press [2D-code].
4-3 Configuring Inspection Items: p. 138
Drag the arrow ( ) at the bottom of the menu to display all of the inspection items.
1 Press [Teach].
2 Input an image of the 2D code.
3 Move the rectangle so that it surrounds the 2D code.
4 Press the [OK] Button.
Note

Table of Contents