5 Press [TEACH] on the lower right of the display.
6 The result of reading the 2D code that was displayed will be displayed along with a confir-
mation dialog box for registration in the master data.
7 Press [Yes] to register the read result in the master data.
The master data contains the character strings from the 2D codes that are registered to verify
whether the read character strings match specific character strings.
8 Press the master data in which the read characters will be registered.
9 Press [Back] to end teaching.
You can use the menu commands that are displayed for at the right of the display to adjust the settings that
resulted from teaching.
[Insp. region]: You can change the measurement region.
[Camera setup]: You can adjust the Camera focus, brightness, and other factors to input a better image.
Adjusting Image Quality: p. 76
[Meas. Parameter]: You can change the type of code to read, the read settings, etc.
Detailed Parameters: p. 196
[Continuous test]: You can start test measurements of displayed images for the settings that were taught.