Setting Up Inspections
Step 3 Judgement condition adjustment
Settings can be made to check whether the characters that were read from the workpiece were recognized
correctly.
Differences between the references that were taught for 2D code reading and the actual result of 2D code
reading are detected and conditions are set to determine how accurately 2D codes are read.
[Inspect] [Inspection] [Add item.] [2D-code] [Settings] Tab Page
1 Press [Judgement].
2 Press a setting item to set the OK range.
Set a range for each of the setting items below.
Continuous measurement of the displayed image is
executed.
The measurement values that are displayed on the screen can be changed in the display settings.
Touch
[Display settings] on the right side of the screen to display the display settings screen.
Measured item Range of value Description
Overall quality
Range: 0 to 4
Default value: Lower limit 0, upper limit 4
Can only be displayed and set when the code being read
is Data Matrix and print quality is ON.
Adjusts the upper and lower limits of the overall quality
that is to be judged as OK.
3 Press [OK] to finalize.