Inspecting with the Edge Position Inspection Item
276
FQ2-S/CH User’s Manual
Unstable Edge Position Results
There Is an Edge But It Cannot Be Detected
[Inspect] [Inspection] [Edge Position] [Modify] [Details] Tab Page [Meas. Parameter]
[Edge Level]
Parameter Setting Description
Edge level
Color diff. / density diff. (%)
Range: 0 to 100
Default: 50
When specified by absolute value
Color
Range: 0 to 442
Default: 20
Monochrome
Range: 0 to 255
Default: 20
Set the color change level to detect as an edge.
The edge point is found based on a threshold that is set for a
color change.
If you change the edge level, perform teaching again.
Edge Level
When measuring by relative value (%) of color difference width
An edge is detected in the following way.
1. The color change distribution of the entire measurement region is determined.
2. The minimum color change is 0%. The maximum color change is 100%.
3. The location where the color change intersects with the edge level is detected as the edge.
When measuring by color difference value
The edge threshold is set using the absolute value of the color difference.
Important
Note
100%
50%
0%
Minimum color change
Edge level
Measurement
region
Maximum color change
Measurement region
Noise
Edge threshold (absolute value)