Reading Barcodes
FQ2-S/CH User’s Manual
189
4
Setting Up Inspections
Measurement Data That Can Be Logged (Bar Code)
The following values can be logged as measurement data.
*When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 392
Errors
Error in Teaching
If 2D-codes cannot be read during an automatic registration, a teaching error message is displayed.The reading may
be unstable due to low contrast.
Adjust the brightness to improve the contrast of the 2D-code.
Adjusting the Brightness: p.77
Measured item Range of value Description
Judgement
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−16: Measurement timeout error
This is the judgment result from the measurements.
Num. of characters 0 to 1024 The number of characters read is output.
Note